Energy Efficient Buildings. Chillers. Vapor Compression Refrigeration. In a vapor compression cycle, the compressor raises the temperature of the refrigerant high enough that it can reject heat to the atmosphere, then the expansion valve reduces the temperature of the refrigerant low enough that ... Access This Document
MODEL YK CENTRIFUGAL LIQUID CHILLER STYLE G
MODEL YK CENTRIFUGAL LIQUID CHILLER STYLE G 250 THROUGH 3000 TONS ers with the same full load kW/ton to have an operating cost difference of over 10% due to part load operation. chiller operations, ... View Doc
Centrifugal Chiller Fundamentals
Centrifugal Chiller Fundamentals WME Magnetic-Bearing System 3 2 EVAPORATOR COMPRESSOR 1 4 COP. This single issue affects chiller efficiency more than any other. Using typical chiller operating conditions yields a Carnot efficiency of 0.348 kW/ton. No chiller ... Read Here
Central Chiller Plants - APPA
Central Chiller Plants Presenter: John Vucci Associate Director HVAC Systems 2,000 Ton chiller addition was constructed to expand an existing 2,000 Ton KW/Ton, EER & COP (Coefficient of Performance) ... Access Document
Boiler And Chiller Maintenance For Maximum Efficiency
Chiller basics Chiller maintenance o Compressor o Evaporator/Condenser o Economizers o Air Handlers Source: DOE EERE Source: NREL Table of Contents 9. (kW/ton) COP EER 0.6 5.9 20 0.75 4.7 16 1.0 3.5 12 1.5 2.3 8 29 Chiller Basics Load Point Cap DB °F Weight Factor ... Read Content
Chiller Application Guide
Chiller Application Guide Chiller Plant Sequence of Operation Chiller full load efficiency ratings are usually given in the form of kW/ton, COP (Coefficient of Performance = kWcooling / kWinput) or EER (Energy Efficiency Ratio = Btucooling/kWhinput). ... Read Here
Chiller - Wikipedia
A chiller is a machine that removes heat from a liquid via a vapor-compression or absorption refrigeration cycle. COP = Current vapor-compression chiller technology is based on the "reverse-Rankine" cycle ... Read Article
Centrifugal Water Chillers
Centrifugal Water Chillers Model CVGF Water-Cooled Hermetic Centrifugal CTV-PRC001-GB Introduction Introducing Trane’s Model CVGF Centrifugal Water Chiller Introduction The basic gear driven centrifugal water chiller design was 0.55 kW/Ton at ARI conditions • Motor cooling vented to ... Return Doc
A chiller As Unique As Your Needs. - Johnson Controls
A chiller as unique as your needs. YORK YVAA AIR-COOLED SCREW CHILLERS ... Read Here
HVAC Made Easy - Selection Tips For Chiller Compressors
HVAC MADE EASY - Selection tips for Chiller Compressors Course Content PART I - REFRIGERATIOIN CHILLERS (VAPOR COMPRESSION MACHINES) HVAC applications operating on chilled water system require a chiller package, which ... Content Retrieval
Catalogue - 23XRV 2013 - CARRIER
Speed Screw Chiller 23XRV High part-load performance: IPLV to 0.299 kW/ton(Air Conditioning, Heating, and Refrigerant Institute (AHRI) integrated part load value) Full Load COP ikW/kW 0.168 0.161 0.158 0.162 0.167 0.163 0.163 343 ... Access This Document